2. A moving coil instrument has a resistance of 0.5 ? and a full scale deflection of 0.1 A. To convert it into an ammeter of 0-10 A the shunt resistance should be

Options

A : 0.004 ?

B : 0.005 ?

C : 0.05 ?

D : 0.1 ?

3. As per BIS there are 6 accuracy classes of instruments.

Options

A : True

B : False

C :

D :

4. A piezoelectric force transducer has a charge sensitivity of 20 pC/N. It is connected to a charge amplifier and overall gain of transducer and amplifier is 50 mV/N. The gain of amplifier is

Options

A : 1 mV/pC

B : 1.5 mV/pC

C : 2.5 mV/pC

D : 4 mV/pC

5. An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured is 5 A. The limiting error is

Options

A : 2%

B : 2.5%

C : 4%

D : 5%

6. An LVDT is used to measure displacement. The LVDT feeds a Voltmeter of 0-5 V range through a 250 gain amplifier. For a displacement 0.5 mm the output of LVDT is 2 mV. The sensitivity of instrument is

Options

A : 0.1 V/mm

B : 0.5 V/mm

C : 1 V/mm

D : 5 V/mm

7. In two wattmeter method of 3 phase power measurement, when does one wattmeter read negative

Options

A : when power factor is less than 0.5 lagging

B : when power factor is greater than 0.5 lagging

C : when power factor is less than 0.5

D : when power factor is unity

8. The household energy meter is

Options

A : indicating instrument

B : recording instrument

C : integrating instrument

D : none of the above

9. Induction wattmeter can be used in

Options

A : ac circuit only

B : dc circuit only

C : both ac and dc circuit

D : ac 3 phase only

10. A standard cell of 1.0185 V is used with a slide wire potentiometer. The balance was obtained at 60 cm. When an unknown emf was connected, the balance was obtained at 82 cm. The magnitude of unknown emf is

Options

A : 1.39 V

B : 0.75 V

C : 13.9 V

D : 7.45 V

1. To increase Q factor of a coil, the wire should be

Options

A : long

B : thin

C : thick

D : long and thin

2. The Lissajous pattern observed on screen of CRO is a straight line inclined at 45° to x axis. If X -plate input is 2 sin ? t , the Y -plate input is

Options

A : 2 sin ? t

B : 2 sin (? t + 45°)

C : 2 sin (? t - 45°)

D : 2 2 sin ? t + 45°)

3. The angle ? for a mica capacitor is about

Options

A : 25°

B : 15°

C : 5°

D : 1°

4. A voltmeter using thermocouples measures

Options

A : rms value

B : peak value

C : average value

D : peak to peak value

5. Which of the following statement is correct for two wattmeters method of power measurement in 3 phase circuit?

Options

A : Power can be measured by this method only for star connected loads

B : When two wattmeters have equal readings power factor is 0.5.

C : When power factor is 1, one of the wattmeters readings is zero

D : When the two wattmeter read equal and opposite, p.f. is zero.

6. In a CRO which of the following is not a part of electron gun

Options

A : cathode

B : grid

C : accelerating anode

D : X - Y plates

7. The coil of a moving iron instrument has a resistance of 500 ? and an inductance of 1 H. It reads 250 V when a 250 V dc is applied. If series resistance is 2000 ?, its reading when fed by 250 V, 50 Hz ac will be

Options

A : 260 V

B : 252 V

C : 250 V

D : 248 V

8. In a ballistic galvanometer, a charge of 100 ?C gives a first swing of 25°. The charge required to cause first swing of 50° is

Options

A : 200 ?C

B : 400 ?C

C : 50 ?C

D : 25 ?C

9. In a strain measuring device using a strain gauge, the output quantity is

Options

A : voltage

B : resistance

C : impedance

D : either (a) or (b)

10. Magnetic flux density has the dimensions

Options

A : MI -1 T -2

B : M -1 I -2 T -2

C : ML -3 T -2

D : MI -1 T -3

1. A dynamometer wattmeter is connected in ac circuit. The measured power is

Options

A : rms power

B : average power

C : peak power

D : instantaneous power